The high-efficiency soft capsule machine adopts the current popular soft capsule machine features at home and abroad, uses brand-new technology and materials, and is carefully designed and precision manufactured. It is currently the laboratory-type soft capsule machine with small size, high accuracy and high technology in China.
The abnormal situations that are likely to occur during the operation of the high-efficiency soft capsule machine are as follows:
1. The capsule cannot be separated:
1. The capsule shell needs to be replaced due to its own reasons.
2. The vacuum is too small, which can be seen by looking at the vacuum gauge. There are many reasons why the vacuum is too small. If there is something wrong with the vacuum pump itself, ask a mechanic to repair it or replace the vacuum pump. The trachea separated from the vacuum pump connection to the capsule shell is broken. Replace the trachea. The filter membrane of the vacuum pump is blocked. Clean the filter membrane. There are also reasons such as too small water flow, so replace the water pipe with a larger one. Specific issues require detailed analysis. Here I only list a few simple ones.
3. The gap between the module and the capsule separator is too large. Either adjust the height of the capsule separator, or there is a problem with the module or the telescopic rod in the module. Analysis is required to find solutions. Here, problems are more likely to occur if the medicinal powder is too fine or the medicinal powder is too sticky.
4. The module is not correct. Use the debugging lever to adjust the module until it automatically lands.
5. The medicinal powder is too sticky and blocks the module. The module should be cleaned.
2. The head and tail of the capsule are recessed. Sometimes there is a problem with the capsule itself. I have encountered this many times before, and it was solved by replacing the capsule. Then check the ejector pin to see if the height of the ejector pin needs to be adjusted. Sometimes increasing the force-bearing area of the bladder can also solve the problem. To increase the stress-bearing area of the capsule shell, you need to customize a thicker thimble. I heard this from someone at the capsule manufacturer, but we had never done it at that time.
3. Capsule splitting. This is a very headache and is often encountered. Need to be treated carefully. This phenomenon usually occurs for the following reasons:
1. The reason for the capsule itself is that the cap and body of the capsule are too different. The capsule needs to be replaced.
2. There is too much powder remaining on the module. The module needs to be cleaned.
3. When installing the module, the upper and lower molds are not aligned. Re-align the module. Until the debugging lever can automatically fall into place.
4. In fact, it is also related to the size of the powder particles. In the process of talking with others, others also said that this is the reason. I haven't confirmed it specifically. If this is indeed the reason, then this item should be added when verifying whether the particle size can cause the phenomenon of chipping. If it is confirmed that this phenomenon does occur, then consider whether the screen should be replaced during grain consolidation.
5. Whether the thimble is too high at the locking point of the capsule cap.
6. To solve the problem of inserting and splitting, there is a method you can try, which is to shorten the distance between the upper mold and the top plate. Of course, it will not work if the distance is too short. The principle is: before the insertion and splitting occurs, it is said to be locked. This method does work and is the method I use more often. Once in the past, I found that it was inserted and split, and no matter how I adjusted it, I couldn't solve it. I almost replaced the entire batch of capsule shells that came into the factory. Finally, I used this method to solve the problem of inserting and splitting.
4. The difference in loading capacity is too large. There is no fixed method for this. Readjust the filling lever. This reason is basically directly related to the medicinal powder. If it is related to pharmaceutical powder, for the sake of equipment, please directly refuse filling and ask the granulation station to rework.
5. The distance between the powder scraper and the dosage disk should be 0.5 mm, as long as it does not touch the dosage disk. Increasing or shortening the distance can directly affect the loading capacity. Sometimes the loading capacity is too low and you can try to increase the distance. If the filling volume is too high when the filling rod is not pressurized at a short distance, please directly request the granulation station to rework.
6. The bearings at the outlet of the finished product, the locking area, and the waste bag are blocked. This is basically caused by the entry of the powder. Please clean the bearings in time and apply an appropriate amount of oil. Adding butter to these areas is better than applying engine oil. After cleaning, make sure the bearing is dry, otherwise, it will be blocked again immediately. During each cleanout, the bearings should be removed, cleaned and oiled.