1. Equipment installation and stability: Make sure that the Soft Gel Capsule Machine is installed on a stable, load-bearing ground, the equipment is vertical to the ground, and the bottom is parallel to the ground to ensure stable operation of the equipment.
2. Safety measures: Check whether the machine is equipped with safety measures, such as speed control, emergency stop button, etc., and ensure that they are effective.
3. Threading device: Check whether the threading device is stable and kept clean.
4. Mold and wheel: Check whether the mold, wheel and template have quality problems. If there are any problems, they should be replaced in time.
5. Power supply, air source, hydraulic system: Check the power supply, air source, hydraulic system to ensure normal operation and good grounding.
6. Capsule quality: Check the capsule quality to ensure good quality.
7. Vacuum mixing barrel: Check whether the glue temperature in the vacuum mixing barrel is maintained between the set temperature of 50℃-60℃.
8. Refrigeration switch and water pump switch: Turn on the refrigeration switch and water pump switch.
9. Preheat the glue box, spray body, and infusion tube: Preheat the glue box, spray body, and infusion tube in advance, and the temperature should be close to the glue liquid temperature, and the temperature of the glue box should be slightly higher than the glue liquid temperature.
10. Pressure regulation: Adjust the pressure of the insulated storage barrel or the insulated mixing tank between 0.04-0.06Mpa.
11. Valves and connecting glue pipes: Check whether the valves and connecting glue pipes are tight to prevent glue leakage.
12. Oil rolling system: Add paraffin oil to the oil box of the oil rolling system and make the liquid level higher than the oil outlet.
13. Float in the glue box: Check whether the float in the glue box rotates flexibly, and ensure that the glue delivery port is closed when the float floats up, and the glue delivery port is opened when the float sinks.
14. Rotary direction of the rotary dryer: Check whether the rotary dryer is rotating for soft capsule drying.
15. Main machine and soft capsule mold: Check whether the main machine and soft capsule mold are normal before operation. If there is any abnormality, repair or replace the corresponding parts in time.