💧 Working Principle of a Dropping-Type Soft Capsule Machine
This type utilizes a concentric dual-layer nozzle and surface tension to form seamless, spherical soft capsules, eliminating the need for mechanical cutting or sealing seams.
1. Concentric Dispensing Phase: Gelatin solution is extruded from the outer layer of the nozzle, while the oily drug formulation is extruded from the inner layer at a different, synchronized speed, ensuring the gelatin completely encapsulates a precise dose of the drug.
2. Cooling and Solidification Phase: The encapsulated droplets are dispensed directly into an immiscible cooling medium (such as liquid paraffin). Driven by surface tension, they naturally contract into perfect spheres and gradually cool and solidify.
3. Post-Processing Phase: The formed soft capsules are collected via filtration, then washed and dried to produce finished, seamless, and perfectly spherical soft capsules.
4. Key Process Controls: Precise temperature control is essential-the gelatin solution must be maintained at 75–80°C, the drug formulation at approximately 60°C, and the cooling medium at a stable 13–17°C-to prevent capsule deformation or adhesion.
⚙️ Working Principle of a Rotary Die Soft Capsule Machine
This is the predominant technology used for mass production, enabling the continuous, automated manufacturing of "seamed" (or welded-seam) soft capsules through the compression of two rotating dies.
1. Gelatin Ribbon Preparation: A mixture of gelatin, glycerin, and water is heated into a molten state and spread evenly onto a cooling drum, forming an elastic gelatin ribbon of uniform thickness.
2. Alignment and Filling Phase: Two gelatin ribbons are fed simultaneously between a pair of counter-rotating dies. A wedge-shaped filling nozzle injects a precise dose of the drug formulation into the space between the converging ribbons.
3. Compression and Sealing Phase: As the dies rotate, the cavities on their surfaces compress and seal the filled gelatin ribbons, simultaneously cutting and separating them into individual soft capsules.
4. Drying and Shaping Stage: Once demolded, the soft capsules enter a two-stage drying system-first undergoing pre-drying in a tumble dryer, followed by constant-temperature drying on trays. This process gradually removes excess moisture, ensuring the capsule shells achieve the required hardness and maintain a stable shape.
🔧 Core Control Logic
Both types of equipment utilize high-precision metering pumps to achieve a filling accuracy of ±1%–3%. Throughout the entire process, temperature fluctuations are kept within ±1°C, ensuring high consistency in the weight, wall thickness, and sealing integrity of every soft capsule-fully compliant with GMP manufacturing standards.