What are the ways to deal with abnormalities in the automatic capsule filling machine?

Feb 05, 2021

Leave a message

1. The capsule shell cannot be separated.

1. The bladder shell needs to be replaced due to its own reasons.

2. The vacuum is too small. There are many reasons why the vacuum is too small. If the vacuum pump is the cause, ask a mechanic to repair it or replace the vacuum pump. The trachea separated from the vacuum pump connecting the bladder shell is broken. Replace the trachea. The vacuum pump filter membrane is blocked, clean the filter membrane. In addition, the water flow may be too small, so we have to replace a larger water flow pipe. Of course we have to look at the situation to find out why. Here are just a few briefly listed.

3. The gap between the module and the capsule separator is too large, so that the height of the capsule separator or the module can be adjusted, or there may be a problem with the telescopic rod in the module. Of course this requires analysis. Too fine powder or too sticky powder is most likely to cause problems.

4. The module is not right. Use the debugging lever to adjust the module until it is automatically seated.

5. If the powder is too sticky to block the module, the module should be cleaned.

2. The head and tail of the capsule are recessed, and sometimes the capsule itself has a problem. I have encountered a lot of this before, and it is solved by replacing the capsule. Then check the thimble to see if you need to adjust the height of the thimble. Sometimes increasing the force area of the capsule can also be solved. To increase the force area of the capsule shell is to customize a thicker thimble. This is what people from the capsule manufacturer said, we had not done it at the time.

3. Capsule cleavage, this is very headache, and it is often encountered. Need to be treated carefully. This phenomenon is generally due to the following reasons.

1. The reason of the capsule itself is that the cap and body are too different. The bladder shell needs to be replaced.

2. Too much powder remains on the module. The module needs to be cleaned.

3. When installing the module, the upper and lower molds are not aligned, re-align the modules. Until the debugging rod can automatically fall.

4. In fact, it is also related to the particle size of the powder. In the process of talking with others, others also said that there is this reason. I have not confirmed the details. If this is true, this item should be added when verifying whether the particle size can cause the phenomenon of cleavage. If it is confirmed that this phenomenon does occur, then consider whether the screen should be replaced during the whole grain.

5. Whether the thimble is too high at the cap lock of the capsule.

6. To solve the phenomenon of inserting and splitting, there is a way to try, shorten the distance between the upper mold and the top plate, of course, the distance is too short. The principle is: before the hacking occurs, it is locked. This method is indeed feasible, this is the most method I have used. Once before, I found that there was no way to solve the problem. I almost replaced the entire batch of capsule shells that came into the factory. After the last I used this method to solve the problem of splitting.

Fourth, there is no fixed method for the large difference in loading. Readjust the filling rod. This reason is basically directly related to the powder. If it is related to powder, for equipment considerations, please directly refuse filling and request rework at the granulating post.

5. The distance between the scraper and the dose plate should be 0.5 mm, as long as it does not touch the dose plate. Increase or decrease the distance can directly affect the loading capacity. Sometimes the loading is low, you can try to increase the distance. If the filling rod is not pressurized at the shortest distance, the filling volume is too high, please directly request the rework of the pelletizing post.

6. The bearing blockage at the end of the finished product, at the locking part and removing the waste bag is basically due to the occurrence of the medicine powder entering. Please clean the bearing in time and apply a proper amount of oil. Adding butter to these places is better than oil. After cleaning, make sure that the bearing is dry, otherwise, it will be blocked immediately. Each time the site is cleared, the bearings should be removed for cleaning and oiling.


Send Inquiry