Simple trouble shooting of soft capsule machine

Feb 03, 2020

Leave a message

When the soft capsule machine breaks down abnormally, it may lead to the "timing" error of each cam (i.e. the action sequence error of each cam). During the adjustment, the movement of each mechanism shall not be interfered. When the motor is decelerated and operated continuously by the reducer, the filling turntable will move intermittently through the indexing box of the turntable station. When it is necessary to adjust the "timing" of each cam (i.e. the action sequence of each cam), the handle shall be used to rotate the main motor shaft. When the filling turntable reaches a certain station, the filling turntable will stop from moving for a period of time, during which the filling turntable stops moving, It should be done:
1) * the cam used for capsule distribution on the second station shall send the capsule to the upper module port;
2) * the cam used to separate the cap and body of the capsule by the vacuum separator in the second station shall rise to the lower plane of the lower module, and make the vacuum system generate enough vacuum to make the capsule enter the module and separate the cap and body;
3) In the sixth station, the cam used to remove the capsules that are not separated shall rise to remove the defective capsules;
4) The cam used to lock the filled capsule on the eighth station shall rise to lock the capsule;
5) The cam used to push out the finished product on the ninth station shall rise to push out the finished product.
After the interval period, the filling turntable starts to move to the next position. During the movement, it should be ensured that the movement of each mechanism does not interfere. When the interference occurs, it should be clear whether the cam action is too early or too late. When the cam action is too early, it should loosen the fastening screw of the cam to reverse the cam. When the cam action is too late, it should loosen the fastening screw of the cam to reverse the cam, so as to achieve each There is no interference in the mechanism action. After the "timing" of each cam is adjusted, the main motor shaft shall be continuously rotated by the handle to make the filling turntable run for one or two weeks, and the machine can be powered on and operated only after confirming that the movement of each mechanism does not interfere.
(8) The electrical control system of the machine. There are three operation modes of the machine: inching, automatic and debugging.
The difference between the automatic mode and the debugging mode is that the main motor can only be started when all four side doors of the worktable are closed when the automatic mode is selected; the main motor can also be started when the four side doors of the worktable are opened when the debugging mode is selected. The main motor is stepless regulated by frequency converter, and the frequency converter is started and stopped by the normally open contact of the main contactor to start and stop the main motor.
The machine has an automatic alarm system for empty capsules and drug granules. When empty capsules or drug granules are missing, the alarm will start to prompt the operator to add materials.https://www.wxzoyi.com/

Send Inquiry