During the use of the soft capsule machine, when an abnormal failure occurs, it may cause the "timing" error of each cam (that is, the wrong timing of the action of each cam). When adjusting, ensure that the movement of each mechanism does not interfere. The motor is decelerated and continuously operated by the reducer, and the filling turntable produces intermittent movement through the turntable index box. When it is necessary to adjust the "timing" of each cam (that is, the timing of each cam action), use the handle to rotate the main motor shaft, and when the filling turntable reaches At a certain station, the filling carousel changes from movement to stop and lasts for a period of time. During this period of time when the filling carousel stops moving, the following should be done:
1. The cam used for capsule dispensing on the second station should send the capsule to the upper module port;
2. The cam used to separate the cap and body of the capsule by the vacuum separator in the second station should rise to the lower plane of the lower module, and make the vacuum system generate enough vacuum to allow the capsule to flow into the module and separate the cap and body. ;
3. The cam used to reject the undivided capsules on the sixth station should be raised to eliminate defective capsules;
4. The cam used to lock the filled capsule on the eighth station should rise to lock the capsule;
5. The cam used to push out the finished product on the ninth station should rise to push out the finished product.
6. After the intermittent time period, the filling turntable starts to move to the next station. During the movement, ensure that the movement of each mechanism does not interfere. When interference occurs, you should see whether the cam action is too early or too late, and when the cam action is too late. Loosen the fastening screw of the cam early to reverse the cam. When the action of the cam is too late, loosen the fastening screw of the cam to rotate the cam forward so that the actions of the various mechanisms do not interfere. After the "timing" of each cam is adjusted, the handle should be used to continuously rotate the main motor shaft to make the filling turntable run for one or two weeks. After confirming that the movement of each mechanism does not interfere, the machine can be powered on.
7. The electrical control system of the machine. There are three operating modes of the machine: jog, automatic and debugging.
The difference between the automatic mode and the debugging mode is that when the automatic mode is selected, the four side doors of the work surface are required to be closed to start the main motor; when the debugging mode is selected, the main motor can also be started when the four side doors of the work surface are open. The main motor is steplessly adjusted by the frequency converter, and the frequency converter is started and stopped through the normally open contact of the main contactor to start and stop the main motor.
The machine has an automatic alarm system for empty capsules and lack of medicine particles. When empty capsules or medicine particles are lacking, the alarm will start to prompt the operator to add materials.