Precautions:
1. This equipment is a vibrating machine. The tightening of the screws in each part should be checked frequently. If there is any looseness, it should be tightened in time to prevent malfunction and damage.
2. The plexiglass parts (worktable, medicine board) should be protected from direct sunlight and close to high temperature, and heavy objects must not be placed. The medicine board must be placed vertically or flat to avoid deformation and damage.
3. The electrical shell and body must be grounded to ensure safety. Cut off the power after the work is completed. .
4. After working every day, clean up the residual medicine on the machine and the mold hole, keep the whole machine clean and hygienic, and avoid washing the main machine with water. If the mold on the machine needs to be cleaned, the fixing screws can be loosened and then removed, which is convenient for installation.
Common malfunctions:
1. The vibration is not ideal, adjust the voltage.
2. The reed screw is loose, tighten the screw.
3. The capsule shells are arranged in the worktable, the mouth is higher or lower, adjust the height of the misaligned plate and the guide rail.
4. Too many capsule shells are turned upside down (more than 3%), and the vibrator is improperly adjusted. Due to proper voltage adjustment or the size of the capsule shell is out of specification, select a qualified capsule shell.
5. The capsule shell is stuck on the platen and cannot fall. Replace the capsule shell or adjust the position of the dislocation plate and the plate hole.
6. The mold cannot be reset in the rail, the compression spring at the rear end of the rail is stuck or the capsule is deformed. Reinstall the spring or ejector rod, and push down the stuck capsule with the push rod.
7. The guide plate in the mold is worn, which affects the low rate of capsule fit. Replace with a new mold or loose positioning on both sides, tighten positioning nails, and the capsule is deformed or wet. Replace the capsule shell.