Daily maintenance
1. Clean the surface of the equipment: After each use, the outer shell of the Soft Gel Capsule Machine should be cleaned in time, and the machine body should be wiped with a clean damp cloth to remove dust, drug stains and oil stains on the surface, so as to keep the appearance of the equipment clean and tidy, and prevent stains from corroding the surface of the equipment for a long time.
2. Clean the glue and liquid residue: Disassemble and clean the parts that are in contact with the glue and liquid, such as the gelatin box, material barrel, and feed pump. Use warm water and a soft cloth to carefully clean the interior to ensure that there is no glue and liquid residue to prevent it from drying and agglomerating, which will affect the next use.
3. Check the vulnerable parts: Check whether the roller mold, nozzle, ejector and other parts are worn, deformed or blocked. If the surface of the roller mold is found to be scratched or uneven, it may affect the molding quality of the soft capsule and should be replaced in time; if the nozzle is blocked, it can be unblocked with a special tool.
Regular maintenance
1. Lubricate moving parts: According to the requirements of the equipment manual, regularly add appropriate lubricants to the various moving parts of the Soft Gel Capsule Machine, such as gears, chains, bearings, cams, etc. Generally, after a certain period of operation or a certain production batch, a comprehensive lubrication is required to reduce friction between parts, reduce wear, and ensure smooth operation of the equipment.
2. Calibrate metering devices: Regularly calibrate the feed pump, metering instruments, etc. to ensure the accuracy of the capsule filling amount. For example, standard metering instruments can be used to detect and adjust the discharge volume of the feed pump to ensure that the amount of material liquid filled each time meets the specified standards. It is generally recommended to calibrate once a month or every quarter.
3. Check the electrical system: Regularly check whether the electrical circuit is aging, damaged, loose, etc. to prevent safety hazards such as short circuits and leakage. Check the operating status of the motor, including temperature, noise, vibration, etc. If there is any abnormality, repair or replace it in time. Generally, a comprehensive electrical system inspection is carried out every six months or one year.
4. Clean the cooling system: For Soft Gel Capsule Machine with cooling system, regularly clean the cooling pipes and radiator to prevent scale, impurities, etc. from clogging the pipes and affecting the cooling effect. Special cleaning agents can be used for cleaning, and deep cleaning should be performed at least once a year.
Special situation maintenance
1. Long-term shutdown maintenance: If the Soft Gel Capsule Machine needs to be shut down for a long time, it should be stored in a dry and well-ventilated place after comprehensive cleaning and maintenance. Apply anti-rust oil to parts that are prone to rust, and cover them with plastic film or dust cover to prevent dust and moisture from entering.
2. Post-repair maintenance: After the equipment is repaired and parts are replaced, in addition to inspecting and debugging the new parts, the entire equipment should also be fully maintained. Clean up the debris and oil stains that may be generated during the maintenance process, check whether other parts are affected by the maintenance operation, and ensure that the equipment is restored to the best operating state.