Daily maintenance:
1. Cleaning
After each use, immediately remove the residual gelatin and impurities in the sol system. Use appropriate cleaning agents and tools, such as soft brushes and damp cloths, to wipe the inner wall of the sol tank, the stirring paddle and the heating parts.
For example, use a food-grade alkaline cleaner to remove grease and colloid residues.
2. Check the temperature sensor
Regularly check the accuracy and sensitivity of the temperature sensor to ensure that it can accurately feedback the temperature of the sol.
The temperature sensor can be calibrated by comparing it with a standard thermometer.
3. Observe the stirring parts
Check whether the stirring paddle shows signs of wear, looseness or deformation. If there is a problem, repair or replace it in time.
For example, if the stirring paddle is worn, it may cause uneven stirring and affect the quality of the sol.
Regular maintenance:
1. Lubrication
According to the equipment manufacturer's recommendations, regularly add an appropriate amount of lubricating oil or grease to the bearings and moving parts of the stirring shaft to reduce friction and wear.
Generally, lubrication maintenance is performed every few months.
2. Check the electrical connection
Regularly check whether the electrical connection of the sol system is firm and whether the wires are damaged or aged.
For example, loose electrical connections may cause unstable heating or stirring failure.
3. Clean the heating element
Every once in a while, clean the dirt and carbon deposits on the heating element to ensure good heating effect and energy efficiency.
Special cleaning tools can be used to carefully remove the attachments on the surface of the heating element.
4. Calibrate the control system
The temperature and stirring speed control system of the sol system should be calibrated at least once a year to ensure that its set values ​​match the actual operating values.
This requires the use of professional calibration equipment and tools.
Long-term outage maintenance:
1. Thorough cleaning and drying
If the equipment will be out of service for a long time, it should be thoroughly cleaned and then the inside of the sol system should be completely dried to prevent rust and corrosion.
2. Protective treatment
Apply anti-rust oil to the exposed metal parts and cover them with plastic film or cover for protection.
3. Regular test run
Even during the outage, it is recommended to perform a short test run at regular intervals (such as every 1-2 months) to check whether each component is normal.