1. Immediately stop the machine and investigate environmental and operational factors. Confirm that the calibration environment temperature and humidity are within the range of 20–25℃ and 40–60%RH to avoid interference from thermal expansion and contraction.
Check that the standard weights or calibration capsules are correctly placed, uncontaminated, and not misaligned.
Restart the PLC and HMI system, clear temporary cache errors, and attempt recalibration.
2. Perform a quick hardware initial check. Check for loose, oxidized, or poorly connected sensor signal cables and power cables, especially in vibration areas.
Observe the rolling die, pressure head, and guide rails for residual adhesive or foreign matter causing jamming; clean them promptly.
Use a multimeter to initially test whether the outputs of key sensors (temperature, pressure, displacement) are within the normal range.
3. Replace with standard parts or spare sensors for testing. Replace with known qualified standard weights or calibration capsules to rule out problems with the standard parts themselves.
If a sensor fails repeatedly, temporarily replace it with a spare part for testing to determine if it is a hardware failure.
4. Initiate a dual-verification mechanism. Critical operations should be independently verified by a second person to ensure process compliance and avoid human error.
Confirm whether critical steps such as warm-up and zero-point calibration have been skipped, and correct them promptly.
5. Decide whether to report a repair and minimize losses. If the problem is resolved after a software restart, environmental adjustment, or operational correction, the calibration process can be resumed immediately.
If three consecutive calibration failures occur with consistent deviations, or if the sensor is found to have no signal or is mechanically jammed, a repair request should be submitted immediately, and the manufacturer's technical support should be contacted for intervention.