How to eliminate the fault of soft capsule machine

Sep 16, 2019

Leave a message

When the abnormal failure of the soft capsule machine may lead to the "timing" error of each cam (that is, the motion sequence error of each cam), the adjustment should ensure that the movement of each mechanism does not interfere. Motor through the gear reducer continuous operation, filling turntable by intermittent rotary workstation dividing box, when need to adjust the cam "timing" (i.e., the cam motion sequence), the application of shaft rotates with the main motor, when filling turntable arrived at a particular location, filling turntable from movement to stop and continue for a period of time, the filling turntable stop movement, this period of time should be:

1) the cam used for capsule distribution at the first and second station shall send the capsule to the upper module port;

2) the cam used for separating capsule cap and body on the second and second stations by using vacuum separator should rise to the lower plane of the lower module, and make the vacuum system produce enough vacuum degree to make the capsule go into the module and separate cap and body;

3) the cam used to remove the unseparated capsules on the sixth station shall rise to remove the defective capsules;

4) the cam used for locking the filled capsules on the eighth working position should rise to lock the capsules;

5) the cam used to push out the finished products on the ninth work station shall rise and push out the finished products.

6) After the intermittent period, filling turntable moving to the next station, should guarantee agencies in the process of sports movement interference occurs, when the interference occurs should see the cam movement is too early or too late, when the cam action early should loosen the cam fastening screws to cam reverse, when the cam action too late, should loosen the cam fastening screws to cam clockwise rotation, in order to achieve the agencies interference action will not occur.

7) After the "timing" of each cam is adjusted, the handle should be used to continuously rotate the main motor shaft to make the filling rotary table run for one or two weeks. Only after the movement of each mechanism is ensured not to interfere, can the machine be powered up and run.

8) Electrical control system of the machine. The machine operates in three ways: inching, automatic and debugging.

The difference between automatic mode and debugging mode is that when selecting automatic mode, the four side doors on the working table are required to be closed before starting the main motor.When selecting debugging mode, the main motor can be started when the four side doors on the workbench are opened.The main motor stepless speed regulation through the inverter, through the main contactor normally open contact to start and stop the inverter, in order to start and stop the main motor.

The machine has an automatic alarm system for lack of hollow capsules and drug particles. When there is a lack of hollow capsules or drug particles, the alarm will start and prompt the operator to add materials.