How to calibrate the temperature and humidity sensors of a soft capsule machine?

Nov 17, 2025

Leave a message

Calibration Steps

1. Enter Calibration Mode
Typically, access the parameter setting menu via the function keys on the device (e.g., the "M" key). For example, press the "M" key and select a specific parameter number (e.g., 1236) to enter the temperature calibration interface.

2. Temperature Calibration
In the temperature calibration interface (e.g., parameter 1236), use the arrow keys to adjust the "Temperature Shift Correction" value to correct the deviation between the sensor reading and the standard value.

For dual temperature probes, both temperature probes need to be calibrated separately.

3. Humidity Calibration
In the humidity calibration interface (e.g., parameter 1238), adjust the "Humidity Shift Correction" value to ensure accurate humidity measurement.

Before calibration, ensure the environment is stable and avoid airflow or temperature and humidity fluctuations affecting the results.

4. Calibration Method

Laboratory Calibration: Use a professional temperature and humidity chamber to simulate extreme environments (e.g., -20℃, 50℃, 10%RH, 90%RH), generate a calibration report, and automatically correct the data.

On-site Calibration: Simultaneously measure with a portable standard instrument and sensor, focusing on areas prone to inaccuracy, such as air conditioning vents and corners.

Comparison Method: Compare the sensor to be calibrated with a higher-precision standard sensor (such as a Class II platinum resistance thermometer) in a constant temperature bath, record the deviation, and adjust accordingly.

Maintenance Recommendations:

1. Regular Recalibration: In normal environments, annual calibration is recommended. In dusty or high-temperature environments, this should be reduced to once every six months.

2. Environmental Control: Maintain a stable calibration environment temperature (e.g., 15℃~25℃) and humidity below 85%RH.

Precautions: Before calibration, check the sensor's appearance and connection lines for damage.

If self-calibration is difficult, contact a professional organization for calibration and a detailed report.